Search

Service Hotline
025-87187350 

Copyright: Nanjing Kaitong Automation Technology Co., Ltd.    苏ICP备11040710号    Power by: www.300.cn

PROBLEM SOLVING

Frequently Asked Questions

Page view
1. Alarm 002~004, drive alarm
Generation mechanism: when the driver has an alarm output or the drive alarm high and low level detection logic is opposite;
Removal method:
1) Check whether the driver has alarms (the driver alarm light is on);
2) Check the drive alarm level setting of the corresponding axis, and set the parameter P008 Bit0, Bit1, Bit7 correctly;
2. Alarm 042, no valid tool number is detected
Generation mechanism: the tool post type is set incorrectly or the tool post sender signal is not received;
Removal method:
1) Check the tool post type setting, parameter P010 Bit0 sets the gang tool post or electric tool post;
2) Check the Hall sensor device of the electric tool post or the sending board of the tool post;
3) Set parameter P009 Bit1 (tool position high and low level signal) according to the type of tool post sending;
3. Alarm 036, the three-position switch is not in the starting state
Generation mechanism: The three-position switch is not in the starting state position when starting up;
Removal method:
1) Dial to start position (left side);
4. Alarm 050, U disk list failure
Generation mechanism: U disk initialization failed;
Removal method:
1) Make sure that the U disk is normal and connect to the system U disk interface;
2) The file system of the U disk should be in FAT format (FAT32 or NTFS format is not supported), otherwise use it after formatting it in FAT format;
3) Electronic devices with U disk functions such as MP3 or mobile hard disks are not supported.
5. Alarm 001, emergency stop alarm
Generation mechanism: When the panel emergency stop button is pressed or there is an external emergency stop signal (ESP) input;
Removal method:
1) Unscrew the emergency stop button;
2) Check the external emergency stop input signal (the external emergency stop signal should be in normally open mode);
6. Alarm 006, 010, positive and negative hardware limit alarm
Generation mechanism: LIM+ or LIM- has signal input;
Removal method:
1) Check whether the positive and negative limit switches of each axis have signal generation;
2) The positive and negative limit switches of each axis should be NPN type or normally open type;
7. Alarm 014~020, the positive and negative software component limit alarm of each axis
Generation mechanism: Positive and negative coordinates exceed the parameter setting range;
Release method: 1) Move to the opposite direction;
8. Alarm 037, the cycle start button is continuously pressed
Generation mechanism: The cycle start button is pressed for too long or cannot be released after contact;
Removal method:
1) Whether the setting time of parameter P159 is too short;
2) Whether the button is stuck
9. Alarm 060, system parameter file not found
Generation mechanism: The system parameter file S0001 is lost;
Removal method:
1) In the parameter interface, press the switch key to restore the factory value or restore the backup operation;
2) Import S0001 files in U disk mode;
10. Alarm 061, tool compensation file not found
Generation mechanism: Tool compensation file T0001 is lost;
Removal method:
1) In the tool compensation interface, after inputting tool compensation or trimming tool compensation, the system automatically creates a tool compensation file;
11. Alarm 062, pitch error compensation file not found
Generation mechanism: The pitch error compensation file I0001 is lost;
Removal method:
1) In the pitch error compensation interface, after inputting the compensation value or clearing, the system will automatically create a pitch error compensation file;
Previous article: